У нас вы можете посмотреть бесплатно Part-3: MICOM P444 Relay Configuration | MCL FILE in MICOM Relay | Step by Step 61850 CONFIGURATION или скачать в максимальном доступном качестве, которое было загружено на ютуб. Для скачивания выберите вариант из формы ниже:
Если кнопки скачивания не
загрузились
НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием, пожалуйста напишите в поддержку по адресу внизу
страницы.
Спасибо за использование сервиса savevideohd.ru
Speaker information: Pankaj Kumar Jha Manager, Power Grid Corporation of India Ltd. (Power System Engineer with more than Ten (10) years of industrial experiences.) MiCOM Agile P442 and P444 numerical full scheme distance relays provide flexible and reliable protection, control and monitoring of transmission and sub-transmission lines. They include full scheme 6-zone distance, plus aided directional earth fault (DEF) and comprehensive backup protection for utility lines and cables at all voltage levels, particularly oriented towards transmission grids. S1 Agile is the truly universal IED engineering tool suite for MiCOM P40 Agile relays. All tools are assembled in a palette for simple entry, with intuitive navigation via a few mouse-clicks. S1 Agile supports all existing MiCOM P40 Agile range. In these series of lectures on configuration of Micom P444 and P442 Relays using S1 Agile software, we will cover all the practical aspects of Micom P444/2 Relay configuration using Micom S1 Agile software. This series is spread across three parts as detailed below: 1. Part-1: Configuration of BI/BO and Description of various settings of P444/2 Relay. 2. Part-2: How to configure PSL in Micom P442/4 Relay. 3. Part-3: Creation of MCL Files and IEC61850 engineering of Micom P442/4 Relay. Programmable scheme logic (PSL) allows the user to customise the protection and control functions. It is also used to program the functionality of the optically isolated inputs, relay outputs, LED indications, InterMiCOM (control input) and virtual input/ouput using GOOSE. The programmable scheme logic comprises gate logic and general purpose timers. The gate logic includes OR, AND and majority gate functions, with the ability to invert the inputs and outputs, and provide feedback. All aspects of MiCOM P40 IED configuration are managed using the MiCOM S1 Agile software and are discussed in detail in this session. An incredible amount of time and effort is needed to develop high-quality video tutorials. Each video takes approximately 6-8 hours to complete which includes learning the concept myself, brainstorming creative ways to teach and explain the concepts, creating the presentations (if delivered through PPT mode), Setup of analysis software, video recording, and editing. Your support truly makes all the difference. So, Please like👍🏻, comment and share this video with your friends and keep watching this channel for more such videos in future. #Lightningminds #pankajkumarjha