HOW TO WIRE Conventional Smoke / Heat Detector's ( FDAS) | Fire Alarm Conventional System

In a conventional fire alarm system, all devices such as detectors, sounders and call points are connected to the control panel through separate wire or cable instead of shared one. In other words, the first end of the wire is connected to the detectors and second one to the control panel. In a typical conventional fire alarm system, detectors, sounder and call points are installed and divided into different zones i.e. Zone 1 for basement, Zone 2 for ground floor, Zone 3 for first floor etc. This way, it is easy to identify the exact affecting area to the control room, building management and fire brigade. In other words, the more numbers of zones, the more accurate locating the trigger and fire location. Keep in mind that the very accurate and exact location of fire can’t be found easily in a conventional fire alarm system as compared to the addressable fire alarm system. As the control panel won’t allow you to pinpoint the exact location of individual device or which device has been triggered but only shows the zone location by text, lamp indicator or both in case of emergency. There are four types of fire alarm systems: 1. Conventional fire alarm system 2. Addressable fire alarm system 3. Intelligent fire alarm system 4. Wireless fire alarm system There are five types of detectors: 1. Smoke detector 2. Heat detector 3. Manual call point 4. Carbon monoxide detector 5. Multi sensor detector There are two types of sounder: 1. Bell sounder 2. Electronic sounder How to WIRE Smoke / Heat Detector Addressable:    • HOW TO WIRE Addressable Smoke / Heat ...   If this video helped you out, share it with your friends and give it a thumbs up, please drop a like and leave a suggestion or comment below. ---------------------------------------------------------------------------------------------------------------- Our daily routine as Maintenance Technician in our company. #Please_Like_Share_and_Subscribe​_RACkabayanTECH​​ ➦ For more videos please SUBSCRIBE! 👍 ©️ Disclaimer Under Section 107 of the Copyright Act 1976, allowance is made for "fair use" for purposes such as criticism, comment, news reporting, teaching, scholarship, and research. Fair use is a use permitted by copyright statute that might otherwise be infringing. Non-profit, educational or personal use tips the balance in favor of fair use.

Comments