Русские видео

Сейчас в тренде

Иностранные видео


Скачать с ютуб Chinese Diesel Heater Error Codes E01 - E10 All Codes, Faults & Fixes в хорошем качестве

Chinese Diesel Heater Error Codes E01 - E10 All Codes, Faults & Fixes 3 года назад


Если кнопки скачивания не загрузились НАЖМИТЕ ЗДЕСЬ или обновите страницу
Если возникают проблемы со скачиванием, пожалуйста напишите в поддержку по адресу внизу страницы.
Спасибо за использование сервиса savevideohd.ru



Chinese Diesel Heater Error Codes E01 - E10 All Codes, Faults & Fixes

00:00 - Intro 00:15 - ERROR CODE 01 01:25 - ERROR CODE 02 01:49 - ERROR CODE 03 02:16 - ERROR CODE 04 02:36 - ERROR CODE 05 03:00 - ERROR CODE 06 03:47 - ERROR CODE 07 04:33 - ERROR CODE 08 06:41 - ERROR CODE 09 07:22 - ERROR CODE 10 ERROR CODE 01 This is a low voltage error code that can be caused by a few things Low battery - Charge battery Volt drop - Wire heater direct to battery via inline fuse and if you need to extend your power cable to reach the battery use 6mm2 cable. As an Amazon associate, I earn from qualifying purchases. 6mm2 RED CABLE - https://amzn.to/35sLpGS 6mm2 BLACK CABLE - https://amzn.to/3kbNGdD Controller set to wrong voltage - Check it is set to 12v not 24v in menu settings. password 1688 Damaged battery - Replace battery DECENT AGM LEISURE BATTERY - https://amzn.to/3iFjiJy ERROR CODE 02 This is a very simple one to explain, error code 02 is a high voltage error code. Check that your 240v to 12v transformer is set to 12v if you are using one Make sure your batteries are wired in parallel rather than series if you have multiple batteries. ERROR CODE 03 This is a glow plug error code so most likely replace your glow plug As an ebay partner I earn from qualifying purchases REPLACEMENT GLOW PLUG - https://ebay.us/nbxWwp GLOW PLUG REMOVAL TOOL - https://amzn.to/3iD2KBb REPLACEMENT GLOW PLUG MESH - https://ebay.us/QRb3Hl It could also be a battery with damaged cells - Replace battery/batteries ANOTHER DECENT QUALITY AGM BATTERY - https://ebay.us/Ie4Ic7 ERROR CODE 04 Bad connection - Check all connectors are clipped into place correctly, check the pins inside make contact Stuck piston - Give the pump a light tap a few times on start up PUMP REPLACEMENT - https://amzn.to/3zusFSX ERROR CODE 05 This is an overheating error code Heat outlet - check that there is nothing obstructing your vents Ducting - Check for blockages, harsh bends and that nothing has crushed it in Fan side of heater - make sure there is a gap for the heater to suck in cool air, if there isn't enough cool air flowing over the heater it will overheat ERROR CODE 06 This is a fan error code Fan - make sure nothing is lodged in the fan Fan - make sure the casing isn't pushing against the fan restricting it Fan - make sure both magnets are firmly in place Fan - poor build quality, send it back for replacement TRICLICKS 5KW - https://amzn.to/3i3ti06 AMBIENCO 2KW - https://amzn.to/3qnAIfl ERROR CODE 07 Broken controller - replace controller BLACK 5 BUTTON REMOTE - https://ebay.us/1R3CDy BLUE 5 BUTTON REMOTE - https://ebay.us/YvkRcN BLACK 3 BUTTON REMOTE 2KW - https://ebay.us/eOwfnc Incompatible controller - replace controller and motherboard Bad connection - Check all connections of the blue cable that runs from remote to motherboard. even the solder on controller and motherboard or replace all 3/5KW MOTHERBOARD - https://ebay.us/81L6IE 2KW MOTHERBOARD - http://ebay.us/vqg5nL WIRING LOOM 3/5KW - https://amzn.to/3qUXzzY WIRING LOOM 3/5KW CHEAP BUT LONG WAIT FROM CHINA - https://ebay.us/IGJ0hz ERROR CODE 08 This is a fuel system fault New install - The heater needs priming before starting it Run out of fuel - Make sure you have not run out of fuel, if you have you will need to prime the heater again Low on fuel - If you have tapped into vans fuel tank and van is LOW on fuel fill it up Air bubbles in line - Check pump angle, loose fuel clips, don't drive with heater running, change to the correct fuel line ​ DECENT FUEL LINE - https://ebay.us/8gA1HU ERROR CODE 9 This is a faulty sensor code Faulty sensor - Replace sensor OVERHEAT SENSOR REPLACEMENT - https://ebay.us/exgTMT We have also heard stories of the heat sensor not fixing the 09 error code and the actual thing that did fix it was a new controller for some reason. So if the heat sensor does’t fix the problem try a new controller. Please see above ERROR CODE 10 This is a multiple failed attempts error code So any of the above more than one time, most likely EO8 or Flooded - blow into air intake when the heater is starting up IF YOU WOULD LIKE TO BE ENTERED INTO OUR MONTHLY VAN LIFE PRIZE DRAW WITH SOME AMAZING VAN LIFE PRIZES PLEASE SUBSCRIBE TO OUR BRAND NEW PATREON ACCOUNT FOR £3 A MONTH. YOU WILL AUTOMATICALLY BE ADDED TO THE PRIZE DRAW EACH MONTH...   / vanlifeuksurvivorsguide   JOIN OUR DIESEL HEATER FACEBOOK GROUP   / 212813887001237   CHECK OUT OUR BLOG https://www.vanlifeuksurvivorsguide.c... FOLLOW US ON FACEBOOK   / van-life-uk-the-complete-survivors-guide-1...   FOLLOW US ON INSTAGRAM   / vanlifesurvivorsguide  

Comments